The effect of different volumes and temperatures of saline on the bladder pressure measurement in critically ill patients
2007

Effect of Saline Volume and Temperature on Bladder Pressure in Critically Ill Patients

Sample size: 13 publication Evidence: moderate

Author Information

Author(s): Chiumello Davide, Tallarini Federica, Chierichetti Monica, Polli Federico, Li Bassi Gianluigi, Motta Giuliana, Azzari Serena, Carsenzola Cristian, Gattinoni Luciano

Primary Institution: Dipartimento di Anestesia e Rianimazione, Fondazione IRCCS – 'Ospedale Maggiore Policlinico, Mangiagalli, Regina Elena'

Hypothesis

How do different volumes and temperatures of saline affect bladder pressure measurements in critically ill patients?

Conclusion

Infusing saline at room temperature results in higher bladder pressure compared to body temperature, and the bladder only transmits intra-abdominal pressure accurately with saline volumes between 50 ml and 100 ml.

Supporting Evidence

  • Bladder pressure significantly increased with saline volumes of 150 ml and 200 ml.
  • Infusion of saline at room temperature caused a greater bladder pressure compared to body temperature.
  • The lowest difference between bladder and gastric pressure was obtained with a volume of 50 ml.
  • Four patients had intra-abdominal hypertension with 50 ml saline, increasing to eight with 100 ml saline.

Takeaway

This study shows that using too much saline can give wrong pressure readings in the bladder, and warm saline works better than cold saline.

Methodology

Bladder pressure was measured in 13 mechanically ventilated patients using saline volumes from 50 to 200 ml at body and room temperatures.

Potential Biases

Potential bias due to the small number of patients and specific patient population.

Limitations

The study had a small sample size and was conducted in a single center.

Participant Demographics

13 mechanically ventilated patients (11 male, 2 female; mean age 68 years, BMI 25.5 kg/m2).

Statistical Information

P-Value

p<0.001

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/cc6080

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication