Use of continuous infusion technique with pre-filled elastic pumps for prevention of centrally inserted central catheter occlusion in critically ill patients: A feasibility study
2024

Continuous Infusion Technique to Prevent Catheter Occlusion

Sample size: 46 publication 10 minutes Evidence: moderate

Author Information

Author(s): Wu Kaiping, Jia Wei, Song Kaifei, Yun Wenjuan, Wang Jin, Yi Yaping, Xu Lingyun

Primary Institution: The Affiliated Changzhou Second People’s Hospital of Nanjing Medical University

Hypothesis

Is the continuous infusion technique effective in preventing centrally inserted central catheter occlusion among critically ill patients?

Conclusion

The continuous infusion technique with pre-filled elastic pumps effectively prevents catheter occlusion in critically ill patients without major side effects.

Supporting Evidence

  • Continuous infusion reduced the risk of catheter occlusion by 91.8%.
  • 17.4% of patients in the continuous infusion group experienced occlusion compared to 43.5% in the pulsed infusion group.
  • No significant difference in occlusion rates was found between the two groups.
  • All occluded catheters recovered after intervention.

Takeaway

Using a special pump to slowly push fluid through a catheter helps keep it from getting blocked, which is really important for sick patients.

Methodology

Patients were randomly assigned to receive either continuous infusion or pulsed infusion of flushing fluid, and catheter occlusion rates were monitored.

Limitations

The study had a small sample size and short follow-up period.

Participant Demographics

Participants aged 14 to 80 years, mostly with centrally inserted central catheters inserted through the internal jugular vein.

Statistical Information

P-Value

0.06

Confidence Interval

[0.014–0.487]

Statistical Significance

p=0.06

Digital Object Identifier (DOI)

10.1097/MD.0000000000040930

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication