Subaortic pannus causing complete outlet obstruction after bioprosthetic aortic valve replacement in a patient with left ventricular assist device: a case report
2024

Subaortic Pannus Causing Complete Outlet Obstruction After Aortic Valve Replacement: A Case Report

Sample size: 1 publication Evidence: low

Author Information

Author(s): Krishnaswamy Rohan, Sivasubramaniam Vanathi, Robson Desiree, Hayward Christopher Simon, Muthiah Kavitha, Nuzzi Vincenzo, Fortuni Federico, Sturla Matteo, Addas Alaeldin, Schenker Niklas

Primary Institution: St Vincent’s Hospital, Darlinghurst, Sydney, Australia

Hypothesis

Prolonged LVAD support may facilitate subaortic pannus formation following bioprosthetic aortic valve replacement.

Conclusion

The case illustrates that subaortic pannus can develop asymptomatically in LVAD patients, leading to complete left ventricular outflow tract obstruction.

Supporting Evidence

  • Subaortic pannus formation can occur without symptoms in LVAD patients.
  • Prolonged LVAD support may lead to total left ventricular outflow tract obstruction.
  • Transthoracic echocardiography may not detect subaortic pannus.

Takeaway

This study shows that a growth called pannus can block blood flow in the heart after surgery, even if the patient seems fine.

Methodology

Case report detailing the clinical history, echocardiographic findings, and pathological analysis of the explanted heart.

Limitations

The study is based on a single case report, limiting generalizability.

Participant Demographics

49-year-old Caucasian female with dilated cardiomyopathy.