A comparison of routine [68Ga]Ga-PSMA-11 preparation using Locametz and Illuccix kits
2024

Comparing Locametz and Illuccix Kits for Prostate Cancer Imaging

Sample size: 437 publication 10 minutes Evidence: high

Author Information

Author(s): Wang Ivan E., Morrissette Luke J., Wong Ka Kit, Brooks Allen F., Dakanali Marianna, Scott Peter J. H.

Primary Institution: University of Michigan

Hypothesis

Which kit, Locametz or Illuccix, is more suitable for routine production of [68Ga]Ga-PSMA-11?

Conclusion

Both Locametz and Illuccix kits provide equivalent clinical images and have similar workflows, making the choice between them dependent on production preferences.

Supporting Evidence

  • Locametz kits had a production success rate of 95.03%.
  • Illuccix kits had a production success rate of 99.22%.
  • Both kits resulted in equivalent clinical images.
  • Using silicone coated needles improved labeling consistency.
  • Vial agitation after adding [68Ga]GaCl3 led to better results.

Takeaway

This study looked at two kits used to make a special medicine for prostate cancer scans. Both kits work well, so doctors can choose based on what they like better.

Methodology

The study compared the production success rates, quality control outcomes, and workflows of Locametz and Illuccix kits over a period of 1.5 years.

Potential Biases

Potential bias in reporting success rates based on the authors' experiences.

Limitations

The study may not account for all variables in different production environments.

Participant Demographics

Participants included radiopharmaceutical manufacturers and clinical staff at the University of Michigan.

Statistical Information

P-Value

p<0.05

Confidence Interval

95% CI: 98.34–98.48

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/s41181-024-00317-4

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication