Fluoride Release in Glass-Ionomer Cements
Author Information
Author(s): Morales-Valenzuela Adriana A, Scougall-Vilchis Rogelio J, Lara-Carrillo Edith, Garcia-Contreras Rene, Salmeron-Valdes Elias N, Aguillón-Sol Lizzeth
Primary Institution: Autonomous University State of Mexico
Hypothesis
The fluoride release of the glass-ionomer cement reinforced with NPs of TiO2 is greater than that released by the conventional glass-ionomer cement.
Conclusion
Mechanical mixing glass-ionomer cement showed a more constant fluoride release and the highest fluoride release after recharge, making it beneficial for clinicians.
Supporting Evidence
- Fluoride release started high on the first day for all GICs.
- Mechanical mixing showed a more constant fluoride release over time.
- Statistically significant differences in fluoride release were found in the first 24 hours.
Takeaway
This study looked at how different types of dental cements release fluoride, which helps prevent cavities. The new mixing method worked better at keeping fluoride levels steady.
Methodology
The study compared three conventional hand mixing glass-ionomer cements and a new mechanical mixing glass-ionomer cement by measuring fluoride release over time.
Limitations
The study's findings may not apply to all types of glass-ionomer cements or mixing methods.
Statistical Information
P-Value
0.000
Statistical Significance
p<0.05
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website