Successful Protein Extraction from Over-Fixed and Long-Term Stored Formalin-Fixed Tissues
2011

Improved Protein Extraction from FFPE Tissues

Sample size: 5 publication Evidence: high

Author Information

Author(s): Wolff Claudia, Schott Christina, Porschewski Peter, Reischauer Bilge, Becker Karl-Friedrich

Primary Institution: Technische Universität München

Hypothesis

The new buffer system will improve protein extraction efficiency from over-fixed and long-term stored FFPE tissues.

Conclusion

The new buffer system allows for significantly higher protein recovery from over-fixed and long-term stored FFPE tissues compared to the established method.

Supporting Evidence

  • The new buffer system allowed a protein recovery of 66% from tissues fixed for 144 hours.
  • Using the established extraction procedure, less than 50% protein recovery was seen.
  • 50% more proteins can be extracted from FFPE blocks stored for 20 years with the new buffer system.

Takeaway

Scientists found a better way to get proteins from old tissue samples, which helps in studying diseases.

Methodology

The study compared protein extraction efficiencies using two buffer systems on various FFPE tissue samples.

Limitations

The study primarily focused on specific tissue types and may not generalize to all FFPE tissues.

Participant Demographics

Tissue samples were obtained from various cancer types and hospitals.