Sensitivity to Sound Differences in Deafened Rats with Cochlear Implants
Author Information
Author(s): Buchholz Sarah, Schnupp Jan W. H., Arndt Susan, Rosskothen-Kuhl Nicole
Primary Institution: Medical Center - University of Freiburg
Hypothesis
Can neonatally deafened rats with bilateral cochlear implants develop sensitivity to interaural level differences (ILDs)?
Conclusion
Neonatally deafened rats fitted with cochlear implants can develop good sensitivity to interaural level differences, comparable to that of normally hearing mammals.
Supporting Evidence
- Rats exhibited high sensitivity to ILDs with thresholds of a few dB at all tested pulse rates.
- 23 out of 24 rats showed good ILD sensitivity at 900 pps.
- The median JND for ILDs was 1.715 dB.
Takeaway
Rats that couldn't hear when they were babies can still learn to tell the difference between sounds coming from the left and right sides when they get special hearing devices.
Methodology
Neonatally deafened rats were trained to lateralize binaural stimuli according to ILD using a 2-alternative forced choice procedure.
Limitations
The study is limited to a specific cohort of rats and may not fully represent human cochlear implant users.
Participant Demographics
24 female Wistar rats, neonatally deafened.
Statistical Information
P-Value
p=0.001
Confidence Interval
95% Wilson confidence intervals for the underlying probability of a ‘right‘ response.
Statistical Significance
p<0.05
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website