Diagnostic Accuracy of Real-Time PCR Assays Targeting 16S rRNA and lipL32 Genes for Human Leptospirosis in Thailand: A Case-Control Study
2011

PCR Tests for Diagnosing Leptospirosis in Thailand

Sample size: 266 publication 10 minutes Evidence: moderate

Author Information

Author(s): Thaipadungpanit Janjira, Chierakul Wirongrong, Wuthiekanun Vanaporn, Limmathurotsakul Direk, Amornchai Premjit, Boonslip Siriphan, Smythe Lee D., Limpaiboon Roongrueng, Hoffmaster Alex R., Day Nicholas P. J., Peacock Sharon J.

Primary Institution: Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand

Hypothesis

The study aims to compare the diagnostic sensitivity and specificity of two real-time PCR assays for leptospirosis.

Conclusion

Early detection of Leptospira using PCR is possible for more than half of patients presenting with leptospirosis and could contribute to individual patient care.

Supporting Evidence

  • The diagnostic sensitivity of the rrs assay was 56%, while the lipL32 assay was 43%.
  • No cases were positive for the lipL32 assay alone.
  • The study included 133 confirmed cases of leptospirosis and 133 controls.
  • The median duration of illness prior to admission was 4 days for cases.
  • The study found that PCR tests could improve patient management in the early stages of leptospirosis.

Takeaway

Doctors can use special tests to find out if someone has leptospirosis, a disease from animals, which helps them treat patients faster.

Methodology

A case-control study comparing two PCR assays in 266 patients (133 cases of leptospirosis and 133 controls).

Potential Biases

Potential bias due to self-medication before hospital presentation.

Limitations

The study may not account for all possible confounding factors affecting diagnostic accuracy.

Participant Demographics

Median age of cases was 35 years, predominantly male (81%), and controls had a median age of 42 years, with 57% male.

Statistical Information

P-Value

p<0.001

Confidence Interval

95% CI 47–64% for rrs assay sensitivity

Statistical Significance

p<0.001

Digital Object Identifier (DOI)

10.1371/journal.pone.0016236

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication