Cardiac Device Infections in Germany: 2015 Study
Author Information
Author(s): Benito Baldauf, Reinhard Vonthein, Ernest W. Lau, Marzia Giaccardi, Ojan Assadian, Philippe Chévalier, Christelle Haddad, Kerstin Bode, Andreas Klöss, Roberto Cemin, Hendrik Bonnemeier
Primary Institution: Hochschule Bremerhaven
Hypothesis
What are the rates of cardiac implantable electronic device infections and related mortality in Germany?
Conclusion
The study found a higher prevalence of acute cardiac device infections than previously reported, with significant mortality rates.
Supporting Evidence
- In 2015, 1,595 patients developed a major CIED infection within three months of the procedure.
- Mortality rates were 8.4% for generator pocket infections and 15.24% for lead-related endocarditis.
- The study identified 60,296 patients who underwent CIED procedures in Germany.
- CIED infections were found to be more prevalent than previously reported.
- Male patients had a higher incidence of CIED infections compared to female patients.
- Patients with CIED infections were generally younger than those undergoing any CIED procedure.
- CIED-related procedures were defined by specific OPS codes for various interventions.
- The study highlights the need for improved infection awareness and adherence to treatment guidelines.
Takeaway
This study looked at how many people got infections from heart devices in Germany and found that more people got infected than we thought.
Methodology
The study used de-identified nationwide administrative claims data from Germany's largest health insurance group to analyze CIED procedures and infections.
Potential Biases
Data accuracy depends on coding practices of healthcare facilities, which may introduce bias.
Limitations
The study relied on billing data, which may underestimate infection rates and does not include outpatient treatment.
Participant Demographics
The cohort included 60,296 patients, with 57.3% male and a median age of 73.5 years.
Statistical Information
Confidence Interval
95%CI 56.9–57.7%
Statistical Significance
p<0.05
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website