Comparing Cup-to-Disc Ratio Measurements in Pediatric Glaucoma Suspects
Author Information
Author(s): Zimmermann Caroline Maria, Cardakli Nur, Kraus Courtney Lynn
Primary Institution: Johns Hopkins University School of Medicine
Hypothesis
Is the cup-to-disc ratio measured by optical coherence tomography (OCT) larger than that measured clinically in pediatric patients suspected of glaucoma?
Conclusion
OCT measurements of cup-to-disc ratio were significantly larger than those obtained through clinical assessment, suggesting OCT may be a better method for evaluating pediatric glaucoma suspects.
Supporting Evidence
- CDR measured by OCT was significantly larger than CDR measured clinically on initial and final presentation.
- Average difference between CDR measured clinically and by OCT was <0.1.
- Majority of participants identified as white or Black/African American.
Takeaway
Doctors used two methods to measure the cup-to-disc ratio in children's eyes to see if they might have glaucoma. They found that one method showed bigger numbers than the other, which could help in checking for eye problems.
Methodology
Retrospective cross-sectional study analyzing 221 eyes from 122 pediatric glaucoma suspects, comparing cup-to-disc ratios measured clinically and by OCT.
Potential Biases
Potential bias due to the retrospective nature of the study and variability in follow-up care.
Limitations
Not all eyes received full ophthalmologic testing at both visits, and the follow-up duration varied among participants.
Participant Demographics
Average age at presentation was 9.0 years; 55% male, 39% white, 39% Black/African American.
Statistical Information
P-Value
p=0.002
Confidence Interval
95% CI: 8.0-9.9
Statistical Significance
p<0.001