Ultrasonographic Changes in Dogs with Cushing’s Syndrome
Author Information
Author(s): Mayr Matthias, Geisen Vera, Unterer Stefan, Wehner Astrid
Primary Institution: Clinic of Small Animal Medicine, LMU Munich, Munich, Germany
Hypothesis
What are the ultrasonographic characteristics of adrenal glands in dogs with Cushing’s syndrome showing partial suppression or escape patterns in the low-dose dexamethasone suppression test?
Conclusion
The study found that partial suppression and escape patterns in the low-dose dexamethasone suppression test are indicative of pituitary-dependent hypercortisolism in dogs.
Supporting Evidence
- PSP and EP occurred in 42.9% and 57.1% of all LDDST results.
- The median maximum width of the left adrenal gland was 0.71 cm and of the right 0.75 cm.
- There was a significant correlation between adrenal gland width and weight.
- Adrenal asymmetry was noted in approximately 20% of dogs.
Takeaway
This study looked at the adrenal glands of dogs with a condition called Cushing's syndrome and found that certain test results can help tell if the problem is due to a pituitary issue.
Methodology
Retrospective evaluation of ultrasonographic adrenal gland size, shape, and echogenicity in dogs diagnosed with Cushing’s syndrome.
Potential Biases
Potential observer-dependent variability in ultrasonographic measurements.
Limitations
The study is retrospective and lacks histopathological confirmation of findings.
Participant Demographics
30 female dogs (61.2%), 19 male dogs (38.8%), median age 11 years, median weight 11.1 kg.
Statistical Information
P-Value
p=0.002 for left adrenal gland width, p=0.017 for right adrenal gland width
Confidence Interval
95% CI for DVTR was 1.7 and for DVTDR was 0.3
Statistical Significance
p<0.05