A Simple Method for Measuring Itopride HCl in Tablets
Author Information
Author(s): Thiruvengada Rajan VS, Mohamed Saleem TS, Ramkanth S, Alagusundaram M, Ganaprakash K, Madhusudhana Chetty C
Primary Institution: Annamacharya College of Pharmacy
Hypothesis
This study aimed to develop a simple and reliable method to quantitate itopride HCl in tablet dosage forms.
Conclusion
A simple and reliable HPLC method for measuring itopride HCl in pharmaceutical dosage formulation has been developed and validated.
Supporting Evidence
- The method was validated for selectivity, linearity, accuracy, and precision.
- The calibration curve was linear in the concentration range of 80-120% with a correlation coefficient of 0.9995.
- The percentage recovery for itopride HCl was 100.01%.
- The method is suitable for routine quality control of itopride HCl in tablet formulations.
Takeaway
Researchers created a quick and easy way to measure a medicine called itopride in tablets, making it easier to check if the medicine is good.
Methodology
An isocratic reversed phase high-performance liquid chromatographic method with UV detection was developed and validated for quantifying itopride HCl.