A Simple RP-HPLC Method for Quantitation of Itopride HCl in Tablet Dosage Form
2010

A Simple Method for Measuring Itopride HCl in Tablets

Sample size: 20 publication Evidence: high

Author Information

Author(s): Thiruvengada Rajan VS, Mohamed Saleem TS, Ramkanth S, Alagusundaram M, Ganaprakash K, Madhusudhana Chetty C

Primary Institution: Annamacharya College of Pharmacy

Hypothesis

This study aimed to develop a simple and reliable method to quantitate itopride HCl in tablet dosage forms.

Conclusion

A simple and reliable HPLC method for measuring itopride HCl in pharmaceutical dosage formulation has been developed and validated.

Supporting Evidence

  • The method was validated for selectivity, linearity, accuracy, and precision.
  • The calibration curve was linear in the concentration range of 80-120% with a correlation coefficient of 0.9995.
  • The percentage recovery for itopride HCl was 100.01%.
  • The method is suitable for routine quality control of itopride HCl in tablet formulations.

Takeaway

Researchers created a quick and easy way to measure a medicine called itopride in tablets, making it easier to check if the medicine is good.

Methodology

An isocratic reversed phase high-performance liquid chromatographic method with UV detection was developed and validated for quantifying itopride HCl.

Digital Object Identifier (DOI)

10.4103/0975-1483.71634

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication