Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units
2011

Effectiveness of Cleaning Podiatry Instruments

Sample size: 378 publication Evidence: high

Author Information

Author(s): Smith Gordon WG, Goldie Frank, Long Steven, Lappin David F, Ramage Gordon, Smith Andrew J

Primary Institution: University of Glasgow

Hypothesis

Is central reprocessing more effective than local reprocessing in reducing protein contamination on podiatry instruments?

Conclusion

Central reprocessing is more effective than local reprocessing in reducing protein contamination on podiatry instruments.

Supporting Evidence

  • 72% of centrally reprocessed instruments had detectable protein.
  • 90% of locally reprocessed instruments had detectable protein.
  • Median protein levels were significantly lower in centrally processed instruments.

Takeaway

This study found that cleaning podiatry tools in a central facility is better at removing leftover proteins than cleaning them locally.

Methodology

Residual protein was measured using a fluorescent assay on 189 instruments reprocessed centrally and 189 instruments reprocessed locally.

Limitations

No significant difference was found in residual protein for Blacks files between the two methods.

Statistical Information

P-Value

p < 0.001

Statistical Significance

p < 0.001

Digital Object Identifier (DOI)

10.1186/1757-1146-4-2

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication