Effectiveness of Cleaning Podiatry Instruments
Author Information
Author(s): Smith Gordon WG, Goldie Frank, Long Steven, Lappin David F, Ramage Gordon, Smith Andrew J
Primary Institution: University of Glasgow
Hypothesis
Is central reprocessing more effective than local reprocessing in reducing protein contamination on podiatry instruments?
Conclusion
Central reprocessing is more effective than local reprocessing in reducing protein contamination on podiatry instruments.
Supporting Evidence
- 72% of centrally reprocessed instruments had detectable protein.
- 90% of locally reprocessed instruments had detectable protein.
- Median protein levels were significantly lower in centrally processed instruments.
Takeaway
This study found that cleaning podiatry tools in a central facility is better at removing leftover proteins than cleaning them locally.
Methodology
Residual protein was measured using a fluorescent assay on 189 instruments reprocessed centrally and 189 instruments reprocessed locally.
Limitations
No significant difference was found in residual protein for Blacks files between the two methods.
Statistical Information
P-Value
p < 0.001
Statistical Significance
p < 0.001
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website