Manually prepared lamellae for Descemet stripping endothelial keratoplasty (Pachy-DSEK): comparison of four dissection depths
2022

Comparing Manual Dissection Depths for Corneal Transplant Preparation

Sample size: 45 publication Evidence: moderate

Author Information

Author(s): Bertino Pedro, Magalhães Renata Soares, de Souza Junior Carlos Jose, Maranhão Lucio de Vieira Leite, Prazeres Tatiana Moura Bastos

Primary Institution: Hospital de Olhos INOB, Brasília, DF, Brazil

Hypothesis

This study aimed to compare four depths of manual dissection for the preparation of Descemet stripping endothelial keratoplasty lamellae.

Conclusion

Setting the incision depth to the central corneal thickness did not result in endothelial perforation and a high percentage of ultrathin lamellae was achieved.

Supporting Evidence

  • Endothelial perforation occurred only in the Pachy+50 group (n=3, 30%).
  • Central lamella’s thickness in Pachy-100, Pachy-50, Pachy-0, and Pachy+50 groups measured 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, and 58 ± 31 µm, respectively.
  • The overall 3.0- and 6.0-mm C/P ratios were 0.97 ± 0.06 and 0.92 ± 0.14, respectively.
  • The best outcome was found in the Pachy-0 group, as 75% of the lamellae measured <130 µm and there was no endothelial perforation.

Takeaway

The study looked at how deep to cut when preparing corneal transplants, finding that cutting to the thickness of the cornea itself works best without causing damage.

Methodology

Human donor corneas were randomized into four groups based on dissection depths, and thicknesses were measured using optical coherence tomography.

Limitations

The study is limited by its small sample size.

Participant Demographics

Human donor corneas from a public local eye bank.

Statistical Information

P-Value

p<0.001

Statistical Significance

p<0.001

Digital Object Identifier (DOI)

10.5935/0004-2749.2022-0076

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication