Reliability of Sentinel Lymph Node Biopsy in Breast Cancer After Chemotherapy
Author Information
Author(s): Chintamani, Tandon Megha, Mishra Ashwani, Agarwal Usha, Saxena Sunita
Primary Institution: Vardhman Mahavir Medical College, Safdarjang Hospital, New Delhi, India
Hypothesis
Is sentinel lymph node biopsy using dye alone accurate after neo-adjuvant chemotherapy in locally advanced breast cancer?
Conclusion
The study confirms that sentinel lymph node biopsy using methylene blue dye is safe and nearly as accurate as dual agent mapping methods.
Supporting Evidence
- The sentinel node identification rate was 100%.
- The sensitivity of SLNB was 86.6%.
- The accuracy of SLNB was 93.3%.
- 50% of patients were down staged from N1 or N2 to N0 after chemotherapy.
Takeaway
Doctors can use a special dye to find lymph nodes in breast cancer patients after chemotherapy, and it works really well.
Methodology
Thirty patients with locally advanced breast cancer received neo-adjuvant chemotherapy and then underwent sentinel lymph node biopsy using methylene blue dye.
Limitations
The study had a small sample size and variability in age distribution.
Participant Demographics
Patients aged 32-85 years, with a mean age of 47.3 years; majority were post-menopausal.
Statistical Information
P-Value
p<0.001
Statistical Significance
p<0.05
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website