3D Imaging of Mouse Arteries Using Optical Projection Tomography
Author Information
Author(s): Kirkby Nicholas S., Low Lucinda, Seckl Jonathan R., Walker Brian R., Webb David J., Hadoke Patrick W. F.
Primary Institution: Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
Hypothesis
Can optical projection tomography (OPT) be used as a rapid and cost-effective method to produce quantifiable 3-dimensional images of intimal lesions within murine arteries?
Conclusion
OPT imaging is a valuable tool for the 3-dimensional evaluation of neointimal and atherosclerotic lesion burden and distribution in mouse arteries.
Supporting Evidence
- Lesion formation was clearly identified and distinguished from the underlying vascular wall using OPT imaging.
- Planimetric measurements of lesion area correlated well with those made from histological sections.
- Measurements of lesion volume were highly reproducible between scans.
Takeaway
This study shows that a special imaging technique can help scientists see and measure problems in blood vessels in 3D, which is much easier than older methods.
Methodology
The study used optical projection tomography to image and quantify vascular lesions in mouse arteries after inducing injury through various methods.
Potential Biases
Potential bias from the optical clearing process which may remove lipid pools from atherosclerotic plaques.
Limitations
Image quality is inferior to microscopic imaging techniques, and the reagents used for optical clearing may alter certain aspects of the specimen.
Participant Demographics
Male C57Bl6/J and ApoE-deficient mice, aged 6 to 12 weeks.