Sensitivity, specificity and predictive values of breast imaging in the detection of cancer
1997

Breast Imaging for Cancer Detection

Sample size: 3014 publication Evidence: high

Author Information

Author(s): LEM Duijml, GL Guit, JOM Zaat, AR Koomen, D Willebrand

Primary Institution: Department of Radiology, Kennemer Gasthuis

Hypothesis

Is the combined use of mammography and breast ultrasonography an appropriate diagnostic tool for selecting patients with symptomatic breast disease who need additional pathological evaluation?

Conclusion

Breast imaging using both mammography and ultrasonography is an effective tool for detecting cancer in symptomatic patients.

Supporting Evidence

  • The sensitivity for breast cancer detection was 92.0% and the specificity was 97.7%.
  • A positive predictive value of 68.0% and a negative predictive value of 99.6% were found.
  • The mean diagnostic delay due to false negatives was 9 months.

Takeaway

Doctors used two types of scans to check for breast cancer in over 3000 patients, and they found that this method works really well.

Methodology

An observational follow-up study using mammography and ultrasound on 3014 patients referred for breast imaging.

Potential Biases

The study may be biased if radiological examinations were not performed before surgery in many breast cancer patients.

Limitations

The actual sensitivity and specificity might be slightly less than calculated due to potential false negatives and the follow-up period.

Participant Demographics

The study included 2994 women and 20 men, with an average age of 50 years.

Statistical Information

Confidence Interval

95% confidence interval 2.2-5.8

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication