Rectal stenosis after circular mechanical anastomosis; the influence of stapler size
2024

Impact of Stapler Size on Rectal Stenosis After Surgery

Sample size: 239 publication Evidence: moderate

Author Information

Author(s): Núria Llorach-Perucho, Ladislao Cayetano-Paniagua, Pau Esteve-Monja, Albert Garcia-Nalda, Josep Bargalló, Xavier Serra-Aracil

Primary Institution: Universitat Autònoma de Barcelona

Hypothesis

The frequency of benign anastomotic stenosis (BAS) after the creation of anastomoses with circular mechanical staplers (CMS) in the middle and lower rectum is non-negligible and related to the diameter of the CMS used.

Conclusion

The use of a 31–33 mm CMS was associated with a lower incidence of benign anastomotic stenosis compared to a 28–29 mm CMS.

Supporting Evidence

  • BAS was recorded in 39 out of 239 patients (16.3%).
  • Rates of BAS were lower in the 31–33 mm group compared to the 28–29 mm group.
  • The use of larger staplers is tentatively recommended to reduce the incidence of BAS.

Takeaway

Using bigger staplers when sewing up the intestines after surgery can help prevent blockages later on.

Methodology

Observational study with prospective data recording of consecutive patients with non-disseminated rectal cancer who underwent low anterior resection with colorectal anastomosis using CMS of different diameters.

Potential Biases

The choice of stapler diameter was subjective and influenced by the surgeon's experience.

Limitations

The study's retrospective design and the absence of randomization in stapler size selection may introduce bias.

Participant Demographics

The majority of participants were men (71.1%), with a median age of 67 years.

Statistical Information

P-Value

0.002

Confidence Interval

95% CI 7.27–23.53

Statistical Significance

p=0.002

Digital Object Identifier (DOI)

10.1007/s00464-024-11306-8

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication