Microstructure and biomechanical characteristics of bone substitutes for trauma and orthopaedic surgery
2011

Characteristics of Bone Substitutes for Surgery

Sample size: 9 publication 10 minutes Evidence: moderate

Author Information

Author(s): Van Lieshout Esther MM, Van Kralingen Gerdine H, El-Massoudi Youssef, Weinans Harrie, Patka Peter

Primary Institution: Erasmus MC, University Medical Centre Rotterdam

Hypothesis

What are the structural and mechanical properties of various bone substitute cements used in orthopaedic trauma surgery?

Conclusion

The study found that different bone substitutes have unique structural properties and compression strengths, which can guide surgeons in selecting appropriate materials for specific clinical situations.

Supporting Evidence

  • The study tested seven calcium phosphate cements, one calcium sulphate cement, and one bioactive glass cement.
  • Mean total porosity ranged from 53% to 0.5% across the different materials.
  • CortossĀ® exhibited the highest compression strength at 47.32 MPa.
  • OstimĀ® had the lowest compression strength at 0.24 MPa.
  • CalcibonĀ® had the highest Young's Modulus at 790 MPa.

Takeaway

This study looked at different materials used to replace bone in surgery and found that they each have different strengths and structures, helping doctors choose the best one for their patients.

Methodology

Nine bone substitute cements were tested for their structural and mechanical properties using micro-CT scanning and unconfined compression tests.

Limitations

The study was limited to in vitro testing and did not assess the biological behavior of the materials in vivo.

Statistical Information

P-Value

p<0.05

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/1471-2474-12-34

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication