Surgical explantation of an infected Lotus Edge valve: a case report
2024

Surgical removal of an infected Lotus Edge valve

Sample size: 1 publication Evidence: low

Author Information

Author(s): Yanagino Yusuke, Kainuma Satoshi, Kawamoto Naonori, Tadokoro Naoki, Kakuta Takashi, Ikuta Ayumi, Tonai Kohei, Fujita Tomoyuki, Fukushima Satsuki

Primary Institution: Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, Japan

Hypothesis

The study aims to report the surgical explantation of a Lotus Edge valve due to prosthetic valve endocarditis and aortic annular abscess.

Conclusion

The Lotus Edge valve is difficult to remove due to its fixation after deployment, but using cold water may help facilitate its removal.

Supporting Evidence

  • The patient had a history of severe aortic stenosis and underwent TAVR with a Lotus Edge valve.
  • Blood cultures were positive for Streptococcus dysgalactiae subspecies equisimilis.
  • Postoperative echocardiography confirmed favorable prosthetic valve function.

Takeaway

Doctors had to take out a special heart valve from an older man because it got infected, and they found that using cold water helped make the job easier.

Methodology

The surgery involved median sternotomy, cardiopulmonary bypass, and cold-saline irrigation to facilitate valve removal.

Limitations

The case report is based on a single patient, limiting generalizability.