Volatility of 3,4-Benzpyrene in Relation to the Collection of Smoke Samples
1958

Volatility of 3,4-Benzpyrene in Smoke Samples

publication Evidence: moderate

Author Information

Author(s): B. T. Commins, P. J. Lawther

Primary Institution: Medical Research Council Group for Research on Atmospheric Pollution, St. Bartholamew's Hospital, London

Hypothesis

The study investigates the volatility of 3,4-benzpyrene in smoke samples collected at different temperatures and air flow rates.

Conclusion

The study found that 3,4-benzpyrene does not volatilize at room temperature but does so significantly at higher temperatures.

Supporting Evidence

  • No fluorescent was detected in the liquid paraffin indicating no vapour of 3,4-benzpyrene in town air.
  • 100% recovery of 3,4-benzpyrene was achieved after passing 120 cubic metres of air at 180 C.
  • No loss of 3,4-benzpyrene was noted at room temperature after prolonged air passage.
  • Appreciable losses of 3,4-benzpyrene occurred at 1000 C. even at low air flow rates.

Takeaway

The researchers looked at how a chemical called 3,4-benzpyrene behaves when air is filtered through it. They found that it doesn't disappear at normal temperatures but does at very high temperatures.

Methodology

The study involved filtering air through various setups to measure the recovery of 3,4-benzpyrene at different temperatures and air flow rates.

Limitations

The study only focused on 3,4-benzpyrene and did not explore other hydrocarbons or conditions.