Coronary Microvascular Dysfunction Years After Cessation of Anabolic Androgenic Steroid Use
2024

Coronary Dysfunction After Stopping Anabolic Steroid Use

Sample size: 90 publication 10 minutes Evidence: moderate

Author Information

Author(s): Bulut Yeliz MD, Rasmussen Jon Jarløv MD PhD, Brandt-Jacobsen Niels MD PhD, Frystyk Jan MD PhD DMSc, Thevis Mario PhD, Schou Morten MD PhD, Gustafsson Finn MD PhD DMSc, Hasbak Philip MD DMSc, Kistorp Caroline MD PhD

Primary Institution: Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark

Hypothesis

Is the use of supraphysiologic doses of anabolic androgenic steroids (AASs) associated with persistent coronary microvascular dysfunction?

Conclusion

The study suggests that AAS use may lead to impaired myocardial flow reserve, which can persist even years after stopping use.

Supporting Evidence

  • The prevalence of impaired myocardial flow reserve was higher among those with current and former AAS use compared to controls.
  • Among individuals with former AAS use, the accumulated duration of AAS use was linked to an increased risk of reduced myocardial flow reserve.
  • Impaired myocardial microcirculation was observed even years after cessation of AAS use.

Takeaway

Using steroids can hurt your heart, and even after you stop using them, your heart might still be in trouble.

Methodology

This cross-sectional study measured myocardial flow reserve in men with current and former AAS use compared to controls using cardiac PET/CT.

Potential Biases

Group allocation was based on self-reported AAS history, which could introduce bias.

Limitations

The sample size may not be adequate to assess prevalences of impaired MFR with post hoc adjustment for multiple comparisons.

Participant Demographics

The study included 90 men aged 18 years or older involved in recreational strength training.

Statistical Information

P-Value

P = .02

Confidence Interval

95% CI, 0.9-2.5

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1001/jamanetworkopen.2024.51013

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication