The Influence of Injection Rate on the Hypnotic Effect of Propofol during Anesthesia: A Randomized Trial
2006

The Effect of Propofol Injection Rate on Anesthesia

Sample size: 99 publication Evidence: moderate

Author Information

Author(s): Blum Jasmin, Kochs Eberhard, Forster Nicole, Schneider Gerhard

Primary Institution: Technische Universität München, Klinikum rechts der Isar, Munich, Germany

Hypothesis

Does the rate of propofol injection influence its maximum hypnotic effect during anesthesia?

Conclusion

Faster injection rates of propofol lead to a higher hypnotic effect compared to slower rates.

Supporting Evidence

  • The lowest BISmin was observed in the group with the fastest injection rate (5 s).
  • Significant differences in BISmin were found between the fastest (5 s) and slowest (240 s) injection rates.
  • No significant differences in hemodynamic parameters were observed among the groups.

Takeaway

Injecting propofol quickly makes it work better for anesthesia, while slow injections don't work as well.

Methodology

Randomized, single-blind trial comparing three different propofol injection rates.

Potential Biases

The proprietary nature of the BIS algorithm introduces unknown sources of error.

Limitations

The BIS algorithm used to measure hypnotic effect may not correlate precisely with consciousness levels.

Participant Demographics

99 unpremedicated patients aged 18 to 60 years with ASA physical status 1–3.

Statistical Information

P-Value

p<0.05

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1371/journal.pctr.0010017